Product Image
Saved
Save to wishlist
Product added to your wishlist! View wishlist
Sign in to see your saved products on any device
Product removed from your wishlist! View wishlist
Sign in to see your saved products on any device
Something went wrong. Please try again later.
Product is added to compare already. Please refresh the page.
Product is not found in compare. Please refresh the page.
5 Products already added. Please delete existing selection to add this.

Share this product

Taco 007 Priority Zoning Circulator Pump 1/25 HP 115V
This product ad may change over time
Share ProductShare

Taco 007 Priority Zoning Circulator Pump 1/25 HP 115V

Each Taco 007-ZF5-9 model Priority Zoning Circulator comes with a built-in transformer relay and priority switch so all the wiring is done directly to the circulators PC board making it ideal for adding a zone or an indirect hot water heater.The priority switch allows the installer to choose the zone that requires the most attention and when activate…
Each Taco 007-ZF5-9 model Priority Zoning Circulator comes with a built-in transformer relay and priority switch so all the wiring is done directly to the circulators PC board making it ideal for adding a zone or an indirect hot water heater.The priority switch allows the installer to choose the zone that requires the most attention and when activated run only that circulator. Taco 007-ZF5-9 priority zoning circulator can be used in conjunction with other circulators or zone valves.Gaskets (O-rings) included; Contact Ratings: Terminals R+W: 24VAC Phase 1 Terminals X+X: 24VAC Terminals R+C: 24VAC (Output) 0.5VA (max) Terminal P- Priority: 115VAC Phase 1 5.0 Amps Inrush Current (max) Terminals H+N: 115VAC Phase 1 8.0 Amps Inrush Current (max) Thermostat Ratings: 24VAC SPDT 2-Wire Heating; 24VAC Digital Electronic; 2-Wire Max Draw 30 Milliamps;Flow Range: 0 u2013 23 GPM;Head Range: 0 u2013 10 Feet;Minimum Fluid Temperature: 40u02daF (4u02daC);Maximum Fluid Temperature: 230u00b0F (115u02daC);Maximum Working Pressure: 125 psi;Connection Sizes: 3/4Patented Design;Snap-in PC Board;Removable Quick-Connect Low Voltage terminal strip;Optional Integral Flow Check (IFCu00ae);UL Listed;Simplified Wiring;LED Power Light;100% Factory Tested;Works With Other Circulators or Zone Valves;Universal Thermostat Compatibility;Made in USA;
See more below

Something went wrong. Please try again later.

U
USA_Wal
$399.92
Visit site
delivery truckFree shipping

Description

Each Taco 007-ZF5-9 model Priority Zoning Circulator comes with a built-in transformer relay and priority switch so all the wiring is done directly to the circulators PC board making it ideal for adding a zone or an indirect hot water heater.The priority switch allows the installer to choose the zone that requires the most attention and when activated run only that circulator. Taco 007-ZF5-9 priority zoning circulator can be used in conjunction with other circulators or zone valves.Gaskets (O-rings) included; Contact Ratings: Terminals R+W: 24VAC Phase 1 Terminals X+X: 24VAC Terminals R+C: 24VAC (Output) 0.5VA (max) Terminal P- Priority: 115VAC Phase 1 5.0 Amps Inrush Current (max) Terminals H+N: 115VAC Phase 1 8.0 Amps Inrush Current (max) Thermostat Ratings: 24VAC SPDT 2-Wire Heating; 24VAC Digital Electronic; 2-Wire Max Draw 30 Milliamps;Flow Range: 0 u2013 23 GPM;Head Range: 0 u2013 10 Feet;Minimum Fluid Temperature: 40u02daF (4u02daC);Maximum Fluid Temperature: 230u00b0F (115u02daC);Maximum Working Pressure: 125 psi;Connection Sizes: 3/4Patented Design;Snap-in PC Board;Removable Quick-Connect Low Voltage terminal strip;Optional Integral Flow Check (IFCu00ae);UL Listed;Simplified Wiring;LED Power Light;100% Factory Tested;Works With Other Circulators or Zone Valves;Universal Thermostat Compatibility;Made in USA;
U
USA_Wal
$399.92
Visit site

Price History

Something went wrong. Please try again later.